IO Board 5141000-3 GE LOGIQ E9 for Ultrasound System Repair/Sell

  • 1
  • 2

Brand Name : GE

Model Number : 5141000-3

MOQ : 1

Price : Negotiable

Payment Terms : T/T, Western Union

Delivery Time : 2-4 work days

Packaging Details : Neutral Package

System : GE LOGIQ E9

Category : Medical ultrasonography

Description : Ultrasound Board

Service : Exchange/Repair

Warranty : 60 days

Time Require : 2-4 days

Application : Ultrasound machine

Contact Now

GE LOGIQ E9 Ultrasound IO Board

1.Part number:5141000-3
2.Pre-owned original one ,in excellent condition
3.We provide 60 days warranty

Various GE/Siemens/Toshiba/Hitachi/ Biosound/Medison ultrasonic boards are within our repair/ maintenance range.

IO Board 5141000-3 GE LOGIQ E9 for Ultrasound System Repair/Sell

Other ultrasound parts related to GE that we can offer:

Brand System Description Part Number
GE Logiq P5 APS Power Supply 5140505/5166108/5329667
GE Logiq P5 CPU mainboard 5168431
GE Logiq P5 SYSCONPM 5177848-3
GE Logiq P6 CPU Mainboard
GE Logiq P6 PST Power Supply 5245004/5244555
GE Logiq P6 SYSCONML 5252326-3
GE Logiq S7/Logiq S8 CPS Power supply 6626600 R02/5413249-3
GE Logiq S7 BF128 transmitting board 5392446
GE Logiq S7 GFS board 5371196
GE Logiq S8 BF192 Beamformer 5357234-2
GE Logiq S8 GFS board 5371196-2/5455247
GE Logiq E9/vivid E9 GTX GA200726
GE Logiq E9 MRX Board 5393908/5393912
GE Logiq E9/vivid E9 GFI2 5161631
GE Logiq E9 BEP Power Supply 5393800-3/5166790-2
GE Voluson E6/Voluson E8 RSR KTI301394-2/KTI196357
GE Voluson E6/Voluson E8 RST KTI301148

Knowledge Point

GE LOGIQ E9 IO Board 5141000-3

1. Basic information

  • Name: GE LOGIQ E9 IO Board (Part number 5141000-3)
  • Equipment: GE LOGIQ E9 Ultrasound Diagnostic Instrument
  • Function: IO Board (input and output board) is a key component in the ultrasound diagnostic instrument, responsible for processing signal transmission and communication between the device and external devices (such as probes, displays, keyboards, etc.). In GE LOGIQ E9, IO Board may undertake important tasks such as receiving ultrasound signals from the probe, sending image data to the display, and processing control commands entered by users through the keyboard and mouse.

2. Possible faults and solutions
In the daily use of ultrasound diagnostic instruments, various faults may occur in IO Board, causing the device to fail to work properly. The following are some possible fault phenomena and corresponding solutions:

  • No image display: If the display does not display an image after the device is turned on, there may be a problem with the connection between the IO Board and the display. At this time, you can check whether the connection cable is plugged in tightly and whether it is damaged, and try to re-plug the connection cable to solve the problem.
  • Probe cannot be recognized: If the device cannot recognize the connected probe, there may be a problem with the probe interface on the IO Board. At this point, you can try to replace the probe to rule out the problem with the probe itself. If the problem persists, you need to consider replacing the IO Board.
  • System freeze or restart: In some cases, the failure of the IO Board may cause the system to freeze or restart frequently. This may be caused by damage to the circuit components on the IO Board or software conflicts. At this point, you can try to restart the device to resume normal operation. If the problem cannot be solved, you need to contact a professional maintenance personnel for troubleshooting and repair.

3. Notes

  • Professional maintenance: Since the IO Board is a key component in the ultrasound diagnostic instrument, its maintenance requires professional knowledge and skills. Unauthorized disassembly or repair by non-professionals may cause damage to the device or performance degradation. Therefore, when encountering problems, it is recommended to contact a professional maintenance personnel for processing.
  • Data backup: Before performing any maintenance operations, be sure to back up important data in the device to prevent data loss.
  • Follow the operating manual: When using the GE LOGIQ E9 device, you should strictly follow the instructions in the operating manual to avoid misoperation and equipment damage.

We provide professional ultrasonic plate repair services.10+years of professional maintenance service team.

If you need any product, please feel free to contact us.

Various Ultrasound Systems that we served

GE Ultrasound System
LOGIQ P5, LOGIQ P6, LOGIQ S7, LOGIQ S8, VOLUSON 730, VOLUSON S8, VOLUSON P8, VOLUSON S6, VOLUSON S20, VOLUSON P8, VOLUSON E10, VIVID E9, LOGIQ BOOK, LOGIQ 5, LOGIQ 7, LOGIQ 9, LOGIQ E9, LOGIQ F6, LOGIQ F8, VIVID I, VIVID Q, VOLUSON I, VOLUSON E, VIVID S5, VIVID 3, VIVID 7...

Hitachi-Aloka Ultrasound System
F31, F37, SSD-3500, SSD-3500, SSD-4000, SSD-5000, ALPHA 5, ALPHA 6, ALPHA 7, ALPHA 10, PROSOUND F75, HI VISION AVIUS, HI VISION PREIRUS, EUB-5500, EUB-6500, EUB-7500, EUB-8500, Arietta 60, Arietta 70, Ascendus...

Siemens Ultrasound System
S2000,S3000,SC2000,X300,P500,OXana,Juniper,Omini...


Product Tags:

5141000-3 IO Board

      

Ultrasound System Repair IO Board

      

GE LOGIQ E9 IO Board

      
Quality IO Board 5141000-3 GE LOGIQ E9 for Ultrasound System Repair/Sell for sale